logo-hotline
Xylem Analytics Germany (SI) 
 

Automatic Titrators, TitroLine® 7000

Compact titrator with intelligent exchangeable units with automatic recognition of unit size and reagent data. Thanks to the modern USB- and additional RS232 interfaces, connection of printer, balance and further accessories are possible at the same time. The brilliant, very high-contrast TFT-display allows the easy parameterisation and tracking of the titration curve.

Supplied with:
TL 7000-M1/10: basic unit with magnetic stirrer TM 235 and 10ml exchangeable unit WA 10, incl. amber glass bottle for titration reagent, GL 45 and S 40-bottle adapter, tubes, drip off tube and titration tip.

TL 7000-M1/20: basic unit with magnetic stirrer TM 235 and 20ml exchangeable unit WA 20, incl. amber glass bottle for titration reagent, GL 45 and S 40-bottle adapter, tubes, drip off tube and titration tip.

TL 7000-M1/50: basic unit with magnetic stirrer TM 235 and 50ml exchangeable unit WA 50, incl. amber glass bottle for titration reagent, GL 45 and S 40-bottle adapter, tubes, drip off tube and titration tip.

TL 7000-M2/20: basic unit with magnetic stirrer TM 235 and 20ml exchangeable unit WA 20, incl. amber glass bottle for titration reagent, GL 45 and S 40-bottle adapter, tubes, drip off tube and titration tip. With pH-combination electrode IL-pHT-A120MF-DIN-N and buffer set.
Technical specification
Measuring input pH/mV:pH/mV-input with DIN or BNC socket, TitroLine® 7000 additionally with ID function for automatic detection of electrode
Measuring input Dead Stop:µA-input for double platinum electrode (socket 2 x 4mm), pole voltage adjustable
Temperature:for resistance probes Pt 1000 (socket: 2 x 4mm)
Interfaces:3 x USB (2 x USB-A und 1 x USB-B), 2 x RS-232-C, 1 x LAN
Stirrer connection:TM 235 or alternative paddle stirrer
Keyboard:The unit is operated using the keys on the device itself., the controller TZ 3880 and optional PC-keyboard (USB)
Display:graphics-capable 3,5" TFT display
Exchangeable units:5, 10, 20ml or 50ml exchangeable units with reagent recognition
Burette resolution:20000 steps
Dosing accuracy:systematic error 0.15%, random error 0.05-0.07% in compliance with EN ISO 8655-6
Supply requirements:100-240V; 50/60Hz
Conformity:ISO 8655, part 6
CE-mark:EMC: 2004/108/EG; safety EG- Directive 2006/95
 
 TypeDescriptionPKCat. No.at LLG stock (GR)
TL 7000-M1/10With 10ml exchangeable unit19863160
 TL 7000-M1/20With 20ml exchangeable unit19863161
 TL 7000-M1/50With 50ml exchangeable unit19863162
 TL 7000-M2/20With 20ml exchangeable unit and pH Electrode19863163
Accessories:
Accessories for TITRONIC® / TitroLine®